Pasteurization Training

Home

Training

Seminars

Seminar Agenda

Registration

Quiz

Related Links

High Temperature Short Time (HTST)  Pasteurization for the Milk & Dairy Industry
Assessments -- Consulting Services -- Evaluations -- Training Programs

Test your knowledge of the basic pasteurization process by completing this simple quiz.

1. What is the minimum pasteurization temperature for skim milk in an HTST system?

Correct!

 

161°

Wrong!

 

212°

Wrong!

 

313°

2. What is the minimum pasteurization time for whole milk in an HTST system

Wrong!

 

15 Minutes

Wrong!

 

1.5 Minutes

Correct!

 

15 Seconds

3. What is the name of the pump located between constant level tank and inlet to raw side of regenerator?

Wrong!

 

Cooler Pump

Correct!

 

Booster Pump

Wrong!

 

Diversion Pump

4. The deflector plate that is drilled for draining is found in the cooling section.

Wrong!

 

True

Correct!

 

False

5. Time, temperature and pressure are of no concern when in the full mode of CIP.

Correct!

 

True

Wrong!

 

False

6. What is the minimum pasteurization temperature for cream of 10% or more through a HTST?

Wrong!

 

146°

Wrong!

 

186°

Correct!

 

166°

7. Name the recording pen that records the positions of the flow diversion device found in the STLR?

Correct!

 

Event or Frequency Pen

Wrong!

 

By-pass or Recorder Pen

Wrong!

 

Timing Sync or Controller Pen

8. Name the three provisions which must be met before the booster pump is allowed to operate.

Wrong!

 

1) Back Pressure Valve open; 2) Recorder Controller positive; 3) Air Gap set to 2mm

Correct!

 

1) Timing Pump on;  2) Forward Flow;  3) Pressure Differential Set Point 2#'s or Greater

Wrong!

 

1) Forward Pressure negative; 2)  Anti-Siphon closed; 3) Booster Pump set to 2psi

9. Name the time delay for product mode that is incorporated in the flow diversion controller.

Correct!

 

Flush Delay

Wrong!

 

Diversion Delay

Wrong!

 

By-pass Delay

10.  The basic flow through an HTST is shown below.  Select the next system in the sequence.

 

 

Constant Level Tank

 

 

Raw Side of Regenerator

 

 

Metering Pump

 

 

Heater Section

 

 

Holding Tube

 

 

Indicating Thermometer

 

 

Recording Thermometer Sensor

 

 

Flow Diversion Device

 

 

Pasteurized Side of Regenerator

Wrong!

 

Vacuum Breaker

Wrong!

 

To Filler or Storage

Correct!

 

Cooler Section

[Pasteurization Training] [Training] [Seminars] [Seminar Agenda] [Registration] [Quiz] [Related Links]

Copyright © 2001 Votion Enterprises, Inc.  All Rights Reserved.
Updated 26 Feb 08. 
Questions and comments to
mvk1030@aol.com